• Title of article

    Sequential optimization of a polygeneration plant

  • Author/Authors

    Rubio-Maya، نويسنده , , Carlos and Uche-Marcuello، نويسنده , , Javier and Martيnez، نويسنده , , Amaya، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2011
  • Pages
    9
  • From page
    2861
  • To page
    2869
  • Abstract
    This paper presents a two-steps optimization procedure of a polygeneration unit. The unit simultaneously provides power, heat, cooling and fresh water to a Spanish tourist resort (450 rooms). The first step consist on the synthesis and design of the polygeneration scheme: a “superstructure” was constructed to allow the selection of the appropriate choice and size of the plant components, from both economic and environmental considerations. At that first step, only monthly averaged requirements are considered. The second step includes hourly data and analysis as well as energy storage systems. A detailed modelling of pre-selected devices is then required to also fulfil economic and environmental constraints. As a result, a better performance is obtained compared to the first step. Thus, the two-steps procedure explained here permits the complete design and operation of a decentralized plant producing simultaneously energy (power, heat and cooling) but also desalted water (that is, trigeneration + desalination). Remarkable benefits for the analyzed case study are found: a Net Present Value of almost 300,000 €, a primary energy saving ratio of about 18% and more than 850 ton per year of avoided CO2 emissions.
  • Keywords
    Polygeneration , optimization , Desalted water , Operation , Tourist sector , CCHPW
  • Journal title
    Energy Conversion and Management
  • Serial Year
    2011
  • Journal title
    Energy Conversion and Management
  • Record number

    2335715