• Title of article

    Annual analysis of heat pipe PV/T systems for domestic hot water and electricity production

  • Author/Authors

    Gang، نويسنده , , Pei and Huide، نويسنده , , Fu and Jie، نويسنده , , Ji and Tin-tai، نويسنده , , Chow and Tao، نويسنده , , Zhang، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2012
  • Pages
    14
  • From page
    8
  • To page
    21
  • Abstract
    Heat-pipe photovoltaic/thermal (HP-PV/T) systems can simultaneously provide electrical and thermal energy. Compared with traditional water-type photovoltaic/thermal systems, HP-PV/T systems can be used in cold regions without being frozen with the aid of a carefully selected heat-pipe working fluid. The current research presents a detailed simulation model of the HP-PV/T system. Using this model, the annual electrical and thermal behavior of the HP-PV/T system used in three typical climate areas of China, namely, Hong Kong, Lhasa, and Beijing, are predicted and analyzed. Two HP-PV/T systems, with and without auxiliary heating equipment, are studied annually under four different kinds of hot-water load per unit collecting area (64.5, 77.4, 90.3, and 103.2 kg/m2).
  • Keywords
    heat pipe , Solar collector , Photovoltaic/thermal
  • Journal title
    Energy Conversion and Management
  • Serial Year
    2012
  • Journal title
    Energy Conversion and Management
  • Record number