Title of article :
Conceptual analysis of the precooling stage for LNG processes
Author/Authors :
Castillo، نويسنده , , L. and Majzoub Dahouk، نويسنده , , M. and Di Scipio، نويسنده , , S. and Dorao، نويسنده , , C.A.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
7
From page :
41
To page :
47
Abstract :
More than 95% of the installed LNG facilities by 2012 use a precooling cycle as the first stage of the process. In this work, a technical comparison between different precooling cycles for LNG processes is carried out through computational simulations using Aspen HYSYS®. The aim is to provide future developments with a clear idea of the technical advantages/disadvantages involved in the selection of the process for the precooling cycle. A three stage propane precooled cycle was found to be the most energetically efficient among the studied cases, even better than a two stage mixed refrigerant process (C2/C3) for both climate conditions, warm (25 °C) and cold (6 °C). However, due to the reduced power share that may be reached with a propane cycle temperature restriction, the mixed refrigerant precooling cycle is the preferred alternative under the cold climate condition.
Keywords :
Precooling stage , Refrigeration system , LNG technology
Journal title :
Energy Conversion and Management
Serial Year :
2013
Journal title :
Energy Conversion and Management
Record number :
2336533
Link To Document :
بازگشت