Title of article
Performance analysis of photovoltaic thermal (PVT) water collectors
Author/Authors
Fudholi، نويسنده , , Ahmad and Sopian، نويسنده , , Kamaruzzaman and Yazdi، نويسنده , , Mohammad H. and Ruslan، نويسنده , , Mohd Hafidz and Ibrahim، نويسنده , , Adnan and Kazem، نويسنده , , Hussein A.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2014
Pages
11
From page
641
To page
651
Abstract
The electrical and thermal performances of photovoltaic thermal (PVT) water collectors were determined under 500–800 W/m2 solar radiation levels. At each solar radiation level, mass flow rates ranging from 0.011 kg/s to 0.041 kg/s were introduced. The PVT collectors were tested with respect to PV efficiency, thermal efficiency, and a combination of both (PVT efficiency). The results show that the spiral flow absorber exhibited the highest performance at a solar radiation level of 800 W/m2 and mass flow rate of 0.041 kg/s. This absorber produced a PVT efficiency of 68.4%, a PV efficiency of 13.8%, and a thermal efficiency of 54.6%. It also produced a primary-energy saving efficiency ranging from 79% to 91% at a mass flow rate of 0.011–0.041 kg/s.
Keywords
Primary-energy saving efficiency , Electrical performance , Thermal Performance , Photovoltaic thermal (PVT) , PVT performance
Journal title
Energy Conversion and Management
Serial Year
2014
Journal title
Energy Conversion and Management
Record number
2337437