Title of article
Operational limits of a three level neutral point clamped converter used for controlling a hybrid energy storage system
Author/Authors
Etxeberria، نويسنده , , A. and Vechiu، نويسنده , , I. and Camblong، نويسنده , , H. and Kreckelbergh، نويسنده , , S. and Bacha، نويسنده , , S.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2014
Pages
7
From page
97
To page
103
Abstract
This work analyses the use of a Three-Level Neutral Point Clamped (3LNPC) converter to control the power flow of a Hybrid Energy Storage System (HESS) and at the same time interconnect it with the common AC bus of a microgrid.
ys there is not any storage technology capable of offering a high energy storage capacity, a high power capacity and a fast response at the same time. Therefore, the necessity of hybridising more than one storage technology is a widely accepted idea in order to satisfy the mentioned requirements.
ork shows how the operational limits of the 3LNPC converter can be calculated and integrated in a control structure to facilitate an optimal use of the HESS according to the rules fixed by the user.
Keywords
microgrid , power converters , Renewable energy , Energy Storage , Energy management
Journal title
Energy Conversion and Management
Serial Year
2014
Journal title
Energy Conversion and Management
Record number
2337486
Link To Document