Title of article :
Fifth harmonic and sag impact on PMSG wind turbines with a balancing new strategy for capacitor voltages
Author/Authors :
Seixas، نويسنده , , M. and Melيcio، نويسنده , , R. and Mendes، نويسنده , , V.M.F.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
10
From page :
721
To page :
730
Abstract :
This paper deals with the computing simulation of the impact on permanent magnet synchronous generator wind turbines due to fifth harmonic content and grid voltage decrease. Power converter topologies considered in the simulations are the two-level and the three-level ones. The three-level converters are limited by unbalance voltages in the DC-link capacitors. In order to lessen this limitation, a new control strategy for the selection of the output voltage vectors is proposed. Controller strategies considered in the simulation are respectively based on proportional integral and fractional-order controllers. Finally, a comparison between the results of the simulations with the two controller strategies is presented in order to show the main advantage of the proposed strategy.
Keywords :
Power quality , Permanent magnet generator , Electric grid , Unbalance voltage , Wind Turbines , Fractional-order controller , harmonic behavior
Journal title :
Energy Conversion and Management
Serial Year :
2014
Journal title :
Energy Conversion and Management
Record number :
2337547
Link To Document :
بازگشت