Title of article :
Experimental investigation on heat transfer enhancement due to V-shaped perforated blocks in a rectangular duct of solar air heater
Author/Authors :
Alam، نويسنده , , Tabish and Saini، نويسنده , , R.P. and Saini، نويسنده , , J.S.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Abstract :
In this work, the effect of geometrical parameters of the V-shaped perforated blocks on heat transfer and flow characteristics of rectangular duct, has been investigated experimentally. The experimental investigation encompassed the geometrical parameter namely, relative blockage height (e/H) of 0.4–1.0, relative pitch ratio (P/e) of 4–12 and open area ratio (β) of 5–25% at a fixed angle of attack (α) of 60°. The effect of V-shaped perforated blockages has been investigated for the range of Reynolds number from 2000 to 20,000. The maximum enhancement in Nusselt and friction factor has been found to be 6.76 and 28.84 times to that of smooth duct, respectively. Thermohydraulic performance of V-shaped perforated blockages is also compared to that of V-shaped solid blockages for same geometrical parameters.
Keywords :
solar air heater , Perforation , Nusselt number , V-shaped blocks , Friction factor
Journal title :
Energy Conversion and Management
Journal title :
Energy Conversion and Management