Title of article :
Shear bond strength of different adhesive systems to normal and caries-affected dentin
Author/Authors :
شادمان، نيلوفر نويسنده , , فرزين ابراهيمي، شهرام نويسنده , , مرتضوي لاهيجاني، الهه 1346 نويسنده پزشکي , , قادري، احمد نويسنده Ghaderi, A
Issue Information :
دوفصلنامه با شماره پیاپی 0 سال 2015
Abstract :
BACKGROUND AND AIM: According to the effect of the adhesive and substrate type on the bond strength, examination of
the adhesive is required in all aspects. The aim of this study was to evaluate the shear bond strength of different
adhesive systems to normal dentin (ND) and caries affected dentin (CAD) in permanent teeth.
METHODS: Thirty extracted molars with small occlusal caries were selected. After preparation and determination of ND
and CAD by caries detector, teeth were divided into three groups and treated with one of the two tested adhesives:
Single Bond 2 (SB2), Scotchbond Universal with etch (SBU-ER), and Scotchbond Universal without etch (SBU-SE).
Then composite (Filtek Z-250 XT) were attached to the surfaces and cured. After water storage (24 hours) and
thermocycling (500 cycles 5-55 °C), bond strength was calculated and failure modes were determined by
stereomicroscope. The data were analyzed by one-way ANOVA and post-hoc test [Tukey HSD (honest significant
difference)] and with P ? 0.050 as the level of significance.
RESULTS: Only SBU-ER had significantly higher shear bond strength than SBU-SE in ND (P = 0.027) and CAD
(P = 0.046). Bond strength in SBU-ER the highest and in SBU-SE had the lowest amounts in CAD and ND. There was
no significant difference in each group between ND and CAD.
CONCLUSION: The 2-step etch-and-rinse adhesive (SBU-ER) had higher bond strength to ND and CAD than the selfetch
adhesive (SBU-SE).
Journal title :
Journal of Oral Health and Oral Epidemiology
Journal title :
Journal of Oral Health and Oral Epidemiology