Title of article :
Failure analysis of a silane gas cylinder valve: A case study
Author/Authors :
Peng، نويسنده , , Deng-Jr and Chang، نويسنده , , Yo-Yu and Wu، نويسنده , , Hong-Chun and Tsaur، نويسنده , , Charng-Cheng and Chen، نويسنده , , Jenq-Renn Chen، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
6
From page :
275
To page :
280
Abstract :
A tragic fire occurred in a photovoltaic fabrication plant and resulted in one fatality and significant losses in equipment damage and production interruption. Investigation results indicated that failure of a silane cylinder valve was the main cause. Tests which simulate the incident scenario were conducted to find out the cause of the failure. The test results showed that if a retainer was improperly torqued, an operator could remove and detach the retainer from the valve by hand even without using a wrench. The detached retainer resulted in rapid release of silane and caused a significant explosion. Suggestions on the structure design and operation of silane cylinder valve are also given to prevent similar incidents in the future.
Keywords :
Fire and explosion , Structure design failure , Silane cylinder valve