Title of article :
Entransy analysis of irreversible heat pump using Newton and Dulong–Petit heat transfer laws and relations with its performance
Author/Authors :
Acikkalp، Emin نويسنده Acikkalp, Emin , Emin، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Abstract :
An irreversible heat pump was investigated via entransy analysis and performance criteria. In the analyses, two different convective heat transfer laws were applied to the considered system: the Newton and Dulong–Petit heat transfer laws. The irreversibilities in the system are the result of a finite heat transfer rate, a heat leak and internal irreversibilities, including friction, turbulence etc. In this study, a thermodynamic analysis was performed in detail, and the numerical solutions were used for the conducted analysis. The maximum entransy dissipation (critical points) ranges from 18436.7 kW K to 18855.3 kW K according to y for Newton’s law; however, there is no maximum point for the Dulon–Petit law. It can be concluded from this study that entransy should be used among the basic thermodynamic criteria.
Keywords :
Entropy generation , Entransy efficiency , Irreversible heat pump , Entransy dissipation , Entransy analysis , Exergy efficiency , COP
Journal title :
Energy Conversion and Management
Journal title :
Energy Conversion and Management