Title of article :
Failure analysis of components in compressor vane
Author/Authors :
Lv، نويسنده , , Fengjun and Fu، نويسنده , , Guoru and Cai، نويسنده , , Zhigang and Zhang، نويسنده , , Dong، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Abstract :
The paper presents a failure analysis of components damaged in compressor vane. In order to investigate the damage mechanism and failure causes of components, macroscopic and microscopic observations, microstructural investigations, chemical analysis and hardness measurement have been performed. The results show that the damaged components are caused by fractured blades of 1st stage rotor. In all 1st stage rotor blades, 1# blade is fractured firstly, and is troublemaker in this incident. The fracture mechanism of 1# blade fractured from blade root is due to first order bending vibration fatigue damage. The microstructure, hardness and chemical compositions of 1# blade fracture, all which coincide with technical requirements. The bad shot peening qualities in the surface near blade fracture have important influence on fatigue failure.
Keywords :
BLADE , First order bending vibration fatigue , Shot Peening
Journal title :
Engineering Failure Analysis
Journal title :