Title of article :
Failure analysis of AISI 310S plate in an inert gas generator used in off-shore oil platform
Author/Authors :
Pardal، نويسنده , , Maria J.M. and Carvalho، نويسنده , , S.S. and Barbosa، نويسنده , , C. and Montenegro، نويسنده , , T.R. and Tavares، نويسنده , , S.S.M.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Pages :
10
From page :
1435
To page :
1444
Abstract :
In this work a failure analysis was conducted in a mirror plate made of austenitic stainless steel AISI 310. The mirror is part of the inert gas generator, which is a combustion chamber dedicated to produce inert gas atmosphere (N2 + CO2) to be used during the oil transfer in off-shore platforms. The mirror failed in two distinct regions. The first crack was observed in a region where the temperatures reached were sufficiently high to provoke intense sigma phase precipitation. Other cracks were observed in a region subject to seawater refrigeration, named “cold zone”. These two failures were mitigated in order to propose solutions to avoid similar failures in the new equipment.
Keywords :
Austenitic stainless steel , AISI 310 , Thermal fatigue , Stress corrosion cracking
Journal title :
Engineering Failure Analysis
Serial Year :
2011
Journal title :
Engineering Failure Analysis
Record number :
2339368
Link To Document :
بازگشت