Title of article :
Failure analysis of an electric arc furnace off-gas system
Author/Authors :
Gelfi، نويسنده , , M. and Pola، نويسنده , , A. and Roberti، نويسنده , , R. and La Vecchia، نويسنده , , G.M. and Galli، نويسنده , , E.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Abstract :
The water-cooled ductwork of an electric arc furnace direct evacuation system, installed in a steelmaking plant, experienced premature failure.
maged pipe was investigated by means of optical microscope, scanning electron microscope equipped with energy dispersive X-ray spectroscopy micro-analysis and differential scanning calorimetry, in order to find out the failure causes and to suggest preventive solutions.
udy shows that failure was mainly due to sulphur dewpoint corrosion formed in the hot service and continued also during furnace shutdown. Some modifications to the process were recommended to cope this problem.
Keywords :
Metallurgical failure analysis , microanalysis , Water pipes , Corrosion
Journal title :
Engineering Failure Analysis
Journal title :
Engineering Failure Analysis