Title of article :
Corrosion problems in tinplate cans for storing contact glues for shoes
Author/Authors :
Martins، نويسنده , , J.I.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Pages :
8
From page :
258
To page :
265
Abstract :
Tinplate steel cans were used to store contact glue for shoes. A few months after its storage, the glue displayed a change in colour to a darker brown. The visual inspection of the interior of the cans showed the presence of corrosion of steel, which was evidenced by the typical colour of the iron oxides on the sheet. SEM/EDS and FTIR tests confirmed that the anomaly was due to the following factors: (a) a bad tin coating, small thickness and lack of homogeneity; (b) a degradation of glue, hydrolysis of chloroprene, which led to its acidification. Some recommendations are made to overcome similar situations within the same use of these packages looking at the specifications of tinplate.
Keywords :
Tinplate , Corrosion , Electroplating , Cans , Adhesive glue
Journal title :
Engineering Failure Analysis
Serial Year :
2012
Journal title :
Engineering Failure Analysis
Record number :
2339593
Link To Document :
بازگشت