Title of article :
Failure analysis and modeling of super heater tubes of a waste heat boiler thermally coupled in ammonia oxidation reactor
Author/Authors :
Abbasfard، نويسنده , , Hamed and Ghanbari، نويسنده , , Mehdi and Ghasemi، نويسنده , , Amin and Ghader، نويسنده , , Sattar and Rafsanjani، نويسنده , , Hasan Hashemipour and Moradi، نويسنده , , Ali، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Pages :
8
From page :
285
To page :
292
Abstract :
Repeated failures have been observed in the outlet region of a few super heater tubes made of 1Cr–0.5Mo steel integrated in a waste heat boiler thermally coupled in an ammonia oxidation reactor. A case study of a failed tube running at around 37,440 h was presented. The bulging of some parts of super heater tubes were observed while the tubes were under normal operational temperature of 480 °C and internal pressure of 44 bar. The tube hardness measurements were carried out on the selected super heater tubes including those of ruptured, unruptured and headers. The relatively high value of hardness, 260 HV, of ruptured part compared to other parts indicates that some phase transformation probably occurred for such a low-alloy 1Cr–0.5Mo steel which led to lower thermal resistance. The dynamic modeling including conservation of energy has been developed in order to show the tube overheating. The main root cause of repeated failures of the super heater tubes was short-term overheating following rapid cooling of the tubes due to sudden stoppage of steam flow inside connecting tubes in the event of unit shut down which reduced the thermal resistance of the tubes over time.
Keywords :
Waste heat boiler , Overheating , Dynamic modeling , Failure analysis , Super heater tubes
Journal title :
Engineering Failure Analysis
Serial Year :
2012
Journal title :
Engineering Failure Analysis
Record number :
2339596