Title of article :
Failure analysis of spiral finned tube on the economizer
Author/Authors :
Liang، نويسنده , , Zhiyuan and Zhao، نويسنده , , QinXin، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
7
From page :
208
To page :
214
Abstract :
This article describes the results of an investigation about the failure of spiral finned tube on a newly designed and retrofitted low pressure economizer in a 300 MW pulverized-coal-fired power plant. In order to find out the failure causes and to suggest preventive measures, phase compositions and macrostructure of the tube metal surface were investigated by X-Ray Diffraction and Scanning Electron Microscope equipped with energy dispersive X-Ray spectroscopy micro-analysis. The results show that the failure was principally owing to comprehensive multiphase erosion, an interaction of the fly ash wearing, flue gas washing and sulfurous acid corrosion. Recommendations are given to minimize such failures.
Keywords :
Wear mechanism , Dew point corrosion , Economizer , Piral finned tube
Journal title :
Engineering Failure Analysis
Serial Year :
2013
Journal title :
Engineering Failure Analysis
Record number :
2339657
Link To Document :
بازگشت