Title of article :
Failure analysis on abnormal wall thinning of heat-transfer titanium tubes of condensers in nuclear power plant Part II: Erosion and cavitation corrosion
Author/Authors :
Chen، نويسنده , , Fei-Jun and Yao، نويسنده , , Cheng and Yang، نويسنده , , Zhen-Guo، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
11
From page :
42
To page :
52
Abstract :
In Part I of the failure analysis on abnormal wall thinning of heat-transfer titanium tubes used in condensers in nuclear power plant, we analyzed the causes and mechanisms of abnormal thinning that commonly happened at the contact part between the tubes and the support plates. This kind of failure was the mainstream failure type in our case and the main causes were found to be eccentric contact wear and three-body contact wear rooted in processing defect of internal borings, corrosion products deposit and sagging, and foreign particles. However, there were still some individual failure tubes with different failure sites and modes and were located under the bypass pipes at the shoulder of the tube tower instead of in its lower part, obviously telling another failure story. In Part II of the failure analysis, material analysis, metallographic examination, mechanical performance tests, macro- and microstructure analysis and composition analysis were conducted. The failure causes were found to be erosion and cavitation corrosion and the synergetic effect of them. Finally, corresponding countermeasures were suggested.
Keywords :
Titanium tube , WALL THINNING , Failure analysis , erosion , Cavitation corrosion
Journal title :
Engineering Failure Analysis
Serial Year :
2014
Journal title :
Engineering Failure Analysis
Record number :
2339992
Link To Document :
بازگشت