Title of article
Fatigue failure of a Slickline wire induced by corrosion pits
Author/Authors
Hormaza، نويسنده , , W. and Castro Güiza، نويسنده , , G.M. and Méndez Moreno، نويسنده , , L.M.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2014
Pages
14
From page
96
To page
109
Abstract
A Slickline wire failed after nearly 400 h of service. In order to find out the main causes and the sequence of this failure, a detailed analysis was carried out on a fracture fragment of this component. This analysis revealed that the operation of the wire produced a series of superficial discontinuities, comprising corrosion pits, fatigue cracking and wear grooves, that provided several stress raisers which served as the initiation point for the failure. Additionally, the manufacturing process introduced some longitudinal cracks that helped in the propagation of the final fracture. Finally, due to the presence of dimples in the last portion of the failure, it could be concluded that the ductility of the material was not compromised.
Keywords
Fatigue failure , Pitting corrosion , Surface cracks , High tensile wire , WEAR
Journal title
Engineering Failure Analysis
Serial Year
2014
Journal title
Engineering Failure Analysis
Record number
2339997
Link To Document