Title of article :
Rotor dynamic response of a centrifugal compressor due to liquid carry over: A case study
Author/Authors :
Al Yahyai، نويسنده , , M. and Mba، نويسنده , , D.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
13
From page :
436
To page :
448
Abstract :
This paper presents a case study in which a high speed gas lift centrifugal compressor experienced significant vibration problems associated with start-up and operation. The two-stage 8-impeller unit was used to compressor natural gas associated with oil production. During operation the unit experienced significant levels of vibration that made its continued operation impossible. A rotor-dynamic analysis of the compressor unit confirmed the presence of significant unbalance mass, a direct result of liquid within the process gas (‘liquid carry over’). Results of the rotor dynamic analysis was validated with field data. In addition, the paper shows the difference in rotor vibration synchronous response for varying molecular gas weights, particularly at critical speed.
Keywords :
Labyrinth seals , molecular weight , Centrifugal compressor , Rotor dynamics , Stiffness coefficients
Journal title :
Engineering Failure Analysis
Serial Year :
2014
Journal title :
Engineering Failure Analysis
Record number :
2340388
Link To Document :
بازگشت