Title of article :
Failure analysis of rolling mill stand coupling
Author/Authors :
Domazet، نويسنده , , K. Luksa، نويسنده , , F. and ?u?njar، نويسنده , , M.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Abstract :
The failure analysis of two slipper couplings showed that both couplings fractured as a result of fatigue. In both cases, the fracture started in the corner between the paddle and the coupling body and propagated around the corner. Both fractures are caused by deficient design of the fillet between the paddle and the coupling body with high stress concentration. In order to extend actual service life, three design modifications have been considered. Numerical analysis showed that redesign of coupling by stiffener between the paddle and the coupling body reduces maximum local and actual service life of couplings can be improved from finite to infinite.
Keywords :
Failure analysis , Fatigue , Slipper coupling
Journal title :
Engineering Failure Analysis
Journal title :