• Title of article

    Failure analysis of connecting bolts used for anchoring streetlights of a mountain highway

  • Author/Authors

    Pilone، نويسنده , , D. and Brotzu، نويسنده , , A. and Felli، نويسنده , , F.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2015
  • Pages
    7
  • From page
    137
  • To page
    143
  • Abstract
    This paper presents a failure analysis of connecting bolts used for holding streetlights inside the tunnels of a mountain highway. The fracture occurred in correspondence to crevices formed in bolted joints. Fractographic and metallurgical studies indicate that the bolt failure is due to a deep crevice corrosion process that is further aggravated by the presence of chlorides coming from the spray formed inside tunnels during the winter when sodium chloride is spread for de-icing roads. ographic studies highlighted also that corrosion affects only bolts, while all the other joints’ components are intact. EDS analyses revealed that the bolt material was a Cu-bearing stainless steel that, in chloride media, has a bad corrosion resistance because Cu destabilises the alloy passive film. Therefore, it is recommended that the bolt material should be changed to prevent similar failures and that in such environment crevices should be avoided in design.
  • Keywords
    Stainless steel , Bolt failure , Corrosion , Chloride media
  • Journal title
    Engineering Failure Analysis
  • Serial Year
    2015
  • Journal title
    Engineering Failure Analysis
  • Record number

    2340535