Title of article :
High-speed photography of compressed human trabecular bone correlates whitening to microscopic damage
Author/Authors :
Thurner، نويسنده , , P.J. and Erickson، نويسنده , , B. and Jungmann، نويسنده , , R. and Schriock، نويسنده , , Z. and Weaver، نويسنده , , J.C. and Fantner، نويسنده , , G.E. and Schitter، نويسنده , , G. and Morse، نويسنده , , D.E. and Hansma، نويسنده , , P.K.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
14
From page :
1928
To page :
1941
Abstract :
Mechanical testing of trabecular bone is mainly motivated by the huge impact of osteoporosis in post-menopausal women and the aged in society in terms of social and health care costs. Trabecular bone loss and impairment of its mechanical properties reduce bone strength and increase fracture risk, especially in vertebrae. It is generally accepted that in addition to bone mineral density, microarchitecture and material properties of bone also play important roles for bone strength and fracture risk. In order to overcome the limitations of standard mechanical tests delivering merely integral information about complicated samples, experiments were designed for step-wise mechanical testing with concurrent imaging of trabecular and cortical bone. In this communication we present an approach for real-time imaging of trabecular bone during compression using high-speed photography and investigate the hypothesis whether the whitening of deformed trabeculae is due to microdamage. Experiments on human trabecular bone samples from a healthy male donor revealed that failure of such samples is highly localized in fracture bands. Moreover, strongly deformed trabeculae were seen to whiten, an effect similar to stress whitening in polymers. Scanning Electron Microscopy of the same regions of interest revealed that whitened trabeculae were strongly damaged by microscopic cracks and mostly failed in delamination. Higher resolution images uncovered mineralized collagen fibrils spanning the cracks. The whitening partially faded after unloading of the samples, presumably due to partial crack closure. Overall, high-speed photography enables microdamage detection in real-time during a mechanical test and provides a correlation to recorded stress strain curves.
Keywords :
trabecular bone , fracture , High-speed photography , Stress-whitening , microdamage , Delamination
Journal title :
ENGINEERING FRACTURE MECHANICS
Serial Year :
2007
Journal title :
ENGINEERING FRACTURE MECHANICS
Record number :
2341842
Link To Document :
بازگشت