Title of article :
Development of a high cycle fatigue testing system and its application to thin aluminum film
Author/Authors :
Bae، نويسنده , , Jong-Sung and Oh، نويسنده , , Chung-Seog and Park، نويسنده , , Kyoung-Seok and Kim، نويسنده , , Sang-Kyo and Lee، نويسنده , , Hak-Joo، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
7
From page :
4958
To page :
4964
Abstract :
The principal goal of this investigation was to develop a feedback controlled high cycle fatigue testing system and to demonstrate its usefulness by acquiring a preliminary stress-life curve of an aluminum film in a very short period of time. A high cycle fatigue testing system having 2.5 N load capacities was constructed and proved reliable, stable and useful in doing long-run fatigue tests. A set of stress-life curves was collected under a mean stress level with 1.16 μm thick aluminum films under closed-loop load control. The system is compact enough to set it up on subsidiary equipment like an optical microscope. A white light interferometric microscope was utilized to observe a specimen’s surface morphology change with fatigue cycles in-situ. The surface roughness was decreased or remained constant in the beginning but started to increase in the later stage.
Keywords :
Aluminum film , Closed-loop control , High cycle fatigue , S–N curve , Surface roughness
Journal title :
ENGINEERING FRACTURE MECHANICS
Serial Year :
2008
Journal title :
ENGINEERING FRACTURE MECHANICS
Record number :
2342600
Link To Document :
بازگشت