Title of article :
Ion cyclotron range of frequency heating with hydrogen and helium minority species in Heliotron E
Author/Authors :
Okada، نويسنده , , H. and Mutoh، نويسنده , , T. and Okamoto، نويسنده , , M. and Ohnishi، نويسنده , , M. and Fukayama، نويسنده , , A. and Zushi، نويسنده , , H. and Kondo، نويسنده , , K. and Mizuuchi، نويسنده , , T. and Beshhou، نويسنده , , S. and Sano، نويسنده , , F. and Nagasaki، نويسنده , , K. and Wakatani، نويسنده , , M. and Obiki، نويسنده , , T.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1995
Pages :
6
From page :
173
To page :
178
Abstract :
In ion cyclotron range of frequency heating of Heliotron E, hydrogen and helium 3 were used as minority species. From the charge exchange neutral particle energy measurement, the bulk deuteron temperature was higher in the helium minority case by 20%–40% in the high power region. Helium minority has an advantage in this experiment because its loss region in the velocity space is small, the ion-ion collision cross-section is large and its charge exchange loss ratio is less than that of hydrogen. In this paper, we discuss the comparison of the heating efficiencies and the power loss by escaping particles between the experimental data and the calculation by the Monte Carlo code. The results of the calculation showed that approximately 40% higher efficiency was obtained in the helium minority case. This results agreed with the experimental data in the higher power region.
Journal title :
Fusion Engineering and Design
Serial Year :
1995
Journal title :
Fusion Engineering and Design
Record number :
2349740
Link To Document :
بازگشت