Title of article :
Applications of the CATHARE and CONTAIN codes in parallel runs
Author/Authors :
Sardain، نويسنده , , P. and Porporat، نويسنده , , M. and Gatt، نويسنده , , J.M. and Marbach، نويسنده , , G.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1998
Pages :
5
From page :
109
To page :
113
Abstract :
The present work discussed the risks and consequences of multiple failure sequences for the Safety and Environmental Assessment of Fusion Power (SEAFP) tokamak concept. We analysed a double LOCA scenario within the divertor cooling loop; it starts with an ex-vessel LOCA, inducing an in-vessel LOCA. The induced in-vessel LOCA is due to a thermal crisis occuring in the plasma facing divertor structures, leading to suddenly enhanced thermo-mechanical stresses likely to cause a rupture. We wanted to calculate, as accurately as possible, the overpressure within the different compartments that are involved in the scenario, in order to verify that the design limits of these compartments are not exceeded. We calculated the transients with the help of the CATHARE code for the coolant loop analysis and the CONTAIN code for the containment analysis. A coupling was made, using the Parallel Virtual Machine (PVM) Sofware system on a Unix computers network; the results are compared to those of a manual coupling.
Journal title :
Fusion Engineering and Design
Serial Year :
1998
Journal title :
Fusion Engineering and Design
Record number :
2350173
Link To Document :
بازگشت