Title of article :
Multichannel heterodyne radiometers with fast-scanning backward-wave oscillators for ECE measurement on HT-7 tokamak
Author/Authors :
Zhang، نويسنده , , S.Y. and Poznyak، نويسنده , , V.I. and Ploskirev، نويسنده , , G. and Kalupin، نويسنده , , D. and Wan، نويسنده , , Y.X. and Xie، نويسنده , , J.K. and Luo، نويسنده , , Jr-Sheng Li، نويسنده , , J.G. and Gao، نويسنده , , X. Steven Wan، نويسنده , , B.N. and Zhang، نويسنده , , X.D. and Wang، نويسنده , , K.J. and Kuang، نويسنده , , G.L.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Pages :
8
From page :
193
To page :
200
Abstract :
Two sets of fast-scanning heterodyne radiometer receiver systems employing backward-wave oscillators (BWOs) in 78–118 and 118–178 GHz were developed and installed for electron cyclotron emission (ECE) measurements on HT-7 superconducting tokamak. The double sideband (DSB) radiometer in 78–118 GHz measures 16 ECE frequency points with a scanning time period of 0.65 ms. The other radiometer in 118–178 GHz consists of one independent channel of DSB heterodyne receiver with intermediate frequency (IF) of 100–500 MHz and two channels of single sideband (SSB) heterodyne receiver that are sensitive to upper sideband and lower sideband individually; the IF frequency of the SSB channels are 1.5 GHz around the local oscillator frequencies with 1 GHz bandwidth. By employing a novel design, this unique radiometer measures 3 ECE frequency points at each of the 16 local oscillator frequency points in 118–178 GHz, and the full band can be swept in 0.65 ms period, thus the radiometer measures 48 ECE frequency points in 0.65 ms in principle. Each of the local oscillators’ frequency points can be preset by program to meet specific physics interests. Horizontal view of ECE was installed to measure electron temperature profiles; vertically viewing optics along a perpendicular chord was also installed to study nonthermal ECE spectra. Preliminary measurement results were presented during ohmic and pellet injection plasmas.
Keywords :
Fast scanning , Heterodyne radiometer , Electron cyclotron emission measurement
Journal title :
Fusion Engineering and Design
Serial Year :
2001
Journal title :
Fusion Engineering and Design
Record number :
2351036
Link To Document :
بازگشت