Title of article :
Simulation study of intentional tritium release experiments in the caisson assembly for tritium safety at the TPL/JAERI
Author/Authors :
Iwai، نويسنده , , Y. and Hayashi، نويسنده , , T. and Kobayashi، نويسنده , , K. and Nishi، نويسنده , , M.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Pages :
13
From page :
523
To page :
535
Abstract :
At the Tritium Process Laboratory (TPL) in Japan Atomic Energy Research Institute (JAERI), Caisson assembly for tritium safety study (CATS) with 12 m3 of large airtight vessel (Caisson) was fabricated for confirmation and enhancement of fusion reactor safety to estimate the tritium behavior in the case, where the tritium leak accident should happen. One of the principal objectives of the present studies is the establishment of simulation method to predict the tritium behavior after the tritium leak accident should happen in a ventilated room. As for the understanding of initial tritium behavior until the tritium concentration become steady, the precise estimation of local flow rate in a room and time-dependent release behavior from the leak point are essential to predict the tritium behavior by simulation code. The three-dimensional eddy flow model considering, tritium-related phenomena was adopted to estimate the local flow rate in the 50 m3/h ventilated Caisson. The time-dependent tritium release behavior from the sample container was calculated by residence time distribution function. The calculated tritium concentrations were in good agreement with the experimental observations. The primary removal tritium behavior was also investigated by another code. Tritium gas concentrations decreased logarithmically to the time by ventilation. These observations were understandable by the reason that the flow in the ventilated Caisson was regarded as the perfectly mixing flow. The concentrations of tritiated water measured, and indications of tritium concentration by tritium monitors became gradually flat. This phenomena called ‘tritium soaking effect’ was found to be reasonably explained by considering the contribution of the exhaustion velocity by ventilation system, and the adsorption and desorption reaction rate of tritiated water on the wall material which is SUS 304. The calculated tritium concentrations were in good agreement with the experimental observations. The effectiveness of these codes was thus proved.
Keywords :
Detritiation system , Reynolds equation , Caisson assembly for tritium safety study
Journal title :
Fusion Engineering and Design
Serial Year :
2001
Journal title :
Fusion Engineering and Design
Record number :
2351271
Link To Document :
بازگشت