Title of article :
Thermal analysis and Ohmic loss estimation of polarizer for ITER ECCD system
Author/Authors :
Saigusa، نويسنده , , M. and Takahashi، نويسنده , , K. and Kashiwa، نويسنده , , Y. and Oishi، نويسنده , , S. and Hoshi، نويسنده , , Y. and Nakahata، نويسنده , , H. and Kasugai، نويسنده , , Anatoly A. and Sakamoto، نويسنده , , K. and Imai، نويسنده , , T.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Pages :
6
From page :
473
To page :
478
Abstract :
A high power polarizer using a single grooved mirror has been developed for an electron cyclotron current drive (ECCD) system of the International Thermonuclear Experimental Reactor (ITER). Two grooved mirrors were tested at a frequency of 170 GHz, rf power of 441 kW and a pulse duration of 0.1–6 s for estimating Ohmic losses. The Ohmic loss of grooved mirror strongly depends not only on the rotation angle of the polarization plane of the incident waves, but also on the mirror rotaion angle. The thermal analysis of the grooved mirror has been performed with the 3D FEM code: FEVA.
Keywords :
ITER ECCD system , polarizer , Ohmic losses , Grooved mirror , Polarization