Title of article :
Advanced data handling for plasma profile control in JT-60
Author/Authors :
Yonekawa، نويسنده , , I. and Sueoka، نويسنده , , M. and Hosoyama، نويسنده , , H. and Kawamata، نويسنده , , Y. and Suzuki، نويسنده , , T. and Kurihara، نويسنده , , K.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Pages :
7
From page :
1897
To page :
1903
Abstract :
A real-time profile control system based on PCI-bus modules has been installed in the existing plasma control system (PCS) to control high performance plasmas. In profile control, pre-programmed profile reference data, which are two-dimensional, must be manipulated as the other mono-dimensional pre-programmed reference data such as plasma current in the discharge parameter set-up and in the post-discharge data archiving process, to re-use of the existing man–machine communication tools. An preprogram algorithm number was introduced to allow the change not only of control gains but also of control algorithm during a discharge, providing flexibility and extensibility to cope with future requirements coming from control studies that are now in progress. This system has been successfully applied to safety factor profile control by lower hybrid radio frequency heating system.
Keywords :
CCS , profile control , Plasma shape reconstruction system , JT-60 , MSE
Journal title :
Fusion Engineering and Design
Serial Year :
2006
Journal title :
Fusion Engineering and Design
Record number :
2353348
Link To Document :
بازگشت