Title of article :
Control processes and machine protection on ASDEX Upgrade
Author/Authors :
Raupp، نويسنده , , G. and Treutterer، نويسنده , , W. and Mertens، نويسنده , , V. and Neu، نويسنده , , G. and Sips، نويسنده , , A. and Zasche، نويسنده , , D. and Zehetbauer، نويسنده , , Th.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
9
From page :
1102
To page :
1110
Abstract :
Safe operation of ASDEX Upgrade is guaranteed by a conventional hierarchy of simple and robust hard-wired systems for personnel and machine protection featuring standardized switch-off procedures. Machine protection and handling of off-normal events is further enhanced and peak and lifetime stress minimized through the plasma control system. Based on a real-time process model supporting safety critical applications with data quality tagging, process self-monitoring, watchdog monitoring and alarm propagation, processes detect complex and critical failures and reliably perform case-sensitive counter measures. Intelligent real-time failure handling is done with hardware or software redundancy and performance degradation, or modification of reference values to continue or terminate discharges with reduced machine stress. Examples implemented so far on ASDEX Upgrade are given, such as recovery from measurement failures, switch-over of redundant actuators, handling of actuator limitations, detection of plasma instabilities, plasma state dependent soft landing, or handling of failed switch-off procedures through breakers disconnecting the machine from grid.
Keywords :
Operation safety , Tokamak control , Off-normal events
Journal title :
Fusion Engineering and Design
Serial Year :
2007
Journal title :
Fusion Engineering and Design
Record number :
2353831
Link To Document :
بازگشت