Title of article :
Development of Quench Detection System for W7-X
Author/Authors :
Birus، نويسنده , , Dietrich and Rummel، نويسنده , , Thomas and Fricke، نويسنده , , Marko and Petry، نويسنده , , Klaus and Demattio، نويسنده , , Horst، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
6
From page :
1400
To page :
1405
Abstract :
The Quench Detection System of W7-X will consist of nearly 400 Quench Detection Units (QDU) for the fast and reliable supervision of the 70 superconducting coils and the 120 superconducting bus bar sections. will be five control racks with about 80 QDU, a data acquisition unit, an ac–dc power supply with integrated dc UPS unit in each of the racks and a PC based data management system as an overlay structure. DU will have a special analogue input circuit realised as a programmable half bridge front end with different polarity-sensing and limiting functions for suppressing high dynamic voltages. Special filter design is included for noise-suppression and over voltage protection. A reconfigurable control/arithmetic unit offers possibilities of future expansions (e.g. all digital evaluation). U acquires and checks the differential voltages of the superconductors permanently. In case of a quench it triggers the fast discharge of the coils and the storage of the voltage signals on the memory unit. The quench signals are in the mV range and have to be clearly identified within a noisy and a high-voltage background within a few milliseconds. DU transfers the stored signal dates via a high-speed RS485 serial interface with 20 kV optical isolation barrier to an industrial type data acquisition unit. A second optically isolated RS485-network enables interconnection of each QDU in the control rack (Compound-Mode of QDU). U are designed with an internal failsafe, programmable self-test and redundancy feature, broken wire check of the quench detection cables and connectors inside and outside of the cryostat of W7-X. U will be fed via an UPS supported 24 V dc bus through a high voltage isolated dc–dc transformer on each unit. sign of the Quench Detection System allows operation under high voltage levels of up to 8 kV and under magnetic stray field levels up to 30 mT. The front end is very well isolated and the outputs of the QDU are strictly separated by optical isolating transformers. The differential inputs are equipped with 500 V short-time over voltage protection. per gives an overview of the design of the first prototype.
Keywords :
High voltage isolation , DATA ACQUISITION , W7-X , Quench Detection System , Fibre optic transmission
Journal title :
Fusion Engineering and Design
Serial Year :
2007
Journal title :
Fusion Engineering and Design
Record number :
2353947
Link To Document :
بازگشت