Abstract :
The tokamak machine monitoring and control system has been developed to avoid machine damages in JT-60 safety operation. It monitors the JT-60 mechanical structures and other sub-components to maintain their conditions. The system adopts the CAMAC digitizers, the Signal Transfer Unit (STU), and the hard-wired interlocks. Over 20 year, it has never been affected by any major troubles except a water leakage in toroidal field coil (TFC). The TFC monitoring system has been developed for the TFC safety with the water leakage from a cooling water channel. It has improved the reliability and efficiency of the TFC operation.
Keywords :
PIO , Water leakage , Toroidal field coil (TFC) , JT-60 , CAMAC