• Title of article

    Development of a new detection system for monitoring high-level tritiated water

  • Author/Authors

    Matsuyama، نويسنده , , Masao، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2008
  • Pages
    4
  • From page
    1438
  • To page
    1441
  • Abstract
    To monitor high-level tritiated water in a fusion fuel circulation system, a new detection system for non-destructive measurements of tritium concentration was specially design and fabricated. A twin-type X-ray detector, which works as a detector of the low energy X-rays induced by β-rays from tritiated water, was equipped with the new detection system. Tritiated water flows in a narrow space surrounded by two X-ray detectors. Basic performance of the new detection system was examined using a poly-methylmethacrylate disk labeled with tritium and tritiated water. It was found that the present detection system satisfied the basic performance for measurements of the low energy X-rays and it is applicable to non-destructive measurements of high-level tritiated water in a flow system.
  • Keywords
    ?-ray-induced X-ray spectrometry , High-level tritiated water , Tritium concentration , Non-destructive measurement , Fusion fuel circulation system
  • Journal title
    Fusion Engineering and Design
  • Serial Year
    2008
  • Journal title
    Fusion Engineering and Design
  • Record number

    2355150