Title of article :
HELOKA facility: Thermo-hydrodynamic model and control
Author/Authors :
Ghidersa، نويسنده , , B.E. and Marchese، نويسنده , , V. and Ionescu-Bujor، نويسنده , , Luciano M. and Ihli، نويسنده , , T.H.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
5
From page :
1792
To page :
1796
Abstract :
This paper presents the thermal-hydrodynamic model used to simulate the behavior of the Helium Loop Karlsruhe (HELOKA) facility and describes the mechanism used to control various loop parameters. An accurate control of the temperature during the warm-up and flat top phases is achieved solely by controlling the heater power. During testing campaign, when the helium flow has to be cooled, the power of the heater is set to zero and the temperature is controlled using a control valve installed in the by-pass of the heater. The adopted solution reduces the harmonic distortions when operating at reduced power while keeping the investment cost low.
Keywords :
Blanket module , Helium loop , Divertor module , Temperature Control , RELAP-3D , ITER
Journal title :
Fusion Engineering and Design
Serial Year :
2008
Journal title :
Fusion Engineering and Design
Record number :
2355382
Link To Document :
بازگشت