Title of article :
Upgrading the NIFS superconductor test facility for JT-60SA cable-in-conduit conductors
Author/Authors :
Obana، نويسنده , , Tetsuhiro and Takahata، نويسنده , , Kazuya and Hamaguchi، نويسنده , , Shinji and Yanagi، نويسنده , , Nagato and Mito، نويسنده , , Toshiyuki and Imagawa، نويسنده , , Shinsaku and Kizu، نويسنده , , Kaname and Tsuchiya، نويسنده , , Katsuhiko and Hoshi، نويسنده , , Ryo and Yoshida، نويسنده , , Kiyoshi، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Pages :
4
From page :
1442
To page :
1445
Abstract :
The superconductor test facility at the National Institute for Fusion Science (NIFS) was upgraded to test cable-in-conduit (CIC) conductors for the JT-60SA equilibrium field (EF) coil. Supercritical helium (SHe) lines were assembled with transfer tubes and a heat exchanger. The CIC conductor was covered with a thermal insulation vessel, filled with gas helium at atmospheric pressure. The temperature of the conductor was varied using a film heater attached to an inlet pipe. Critical current (Ic) and current sharing temperature (Tcs) measurements of the prototype CIC conductor were carried out successfully in the upgraded test facility. During the measurements, the conductor temperature was precisely controlled.
Keywords :
JT-60SA , Supercritical helium , Superconductor test facility , Cable-in-conduit conductor
Journal title :
Fusion Engineering and Design
Serial Year :
2009
Journal title :
Fusion Engineering and Design
Record number :
2356010
Link To Document :
بازگشت