Title of article :
Engineering and maintenance studies of the ITER diagnostic upper port plug
Author/Authors :
Sato، نويسنده , , K. and Ohmori، نويسنده , , J. and Kondoh، نويسنده , , T. and Hatae، نويسنده , , T. and Kajita، نويسنده , , S. and Ishikawa، نويسنده , , M. and Neyatani، نويسنده , , Y. and Ebisawa، نويسنده , , K. and Kusama، نويسنده , , Y.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Pages :
3
From page :
1713
To page :
1715
Abstract :
Engineering analyses have been performed for the representative diagnostic upper port plug of ITER. Maintenance and integration design have been also carried out for the diagnostic components to be installed in the upper port plug. From the electromagnetic and structural analyses, it has come up an important problem to suppress the displacement of the upper port plug rather than to reduce the produced stress. Reducing the electro-magnetic (EM) force will help to decrease the severity of potential displacement. Maximum displacement of the port plug decreases with increase in the number of slits in a manner that the displacement would seem to be less than the design tolerance. A proposed low body roller and inner frame may enhance maintenance and integration. These studies and designs have established the design basis for the diagnostic upper port plug.
Keywords :
Maintenance studies , Port plug , Diagnostic , Structural analysis , ITER
Journal title :
Fusion Engineering and Design
Serial Year :
2009
Journal title :
Fusion Engineering and Design
Record number :
2356072
Link To Document :
بازگشت