Title of article :
East integrated control system
Author/Authors :
Ji، نويسنده , , Zhenshan and Wu، نويسنده , , Yichun and Sun، نويسنده , , Xiaoyang and Li، نويسنده , , Shi and Yang، نويسنده , , Fei and Wang، نويسنده , , Yong and Du، نويسنده , , Xiaoying and Liu، نويسنده , , Dong Mei and Zhang، نويسنده , , Ruirui and Liu، نويسنده , , Lianzhong، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2010
Pages :
6
From page :
509
To page :
514
Abstract :
EAST control system has been developed as network-based distributed control system composed of several subsystems. The integrated control system includes a supervisory control system, many local control systems, machine control and safety interlocks, data acquisition and management. The discharge control system, which is implemented in part of the CODAC (COntrol, Data Access and Communication) system, performs the discharge sequence execution. The development of the EAST integrated control system and commissioning results is presented in this paper.
Keywords :
East , Superconducting tokamak , Central control , Safety interlock , Data Access , Synchronization
Journal title :
Fusion Engineering and Design
Serial Year :
2010
Journal title :
Fusion Engineering and Design
Record number :
2356506
Link To Document :
بازگشت