Title of article :
Data acquisition and real-time bolometer tomography using LabVIEW RT
Author/Authors :
Giannone، نويسنده , , L. and Eich، نويسنده , , T. and Fuchs، نويسنده , , J.C. and Ravindran، نويسنده , , M. and Ruan، نويسنده , , Q. and Wenzel، نويسنده , , L. and Cerna، نويسنده , , M. and Concezzi، نويسنده , , S.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Pages :
4
From page :
1129
To page :
1132
Abstract :
The currently available multi-core PCI Express systems running LabVIEW RT (real-time), equipped with FPGA cards for data acquisition and real-time parallel signal processing, greatly shorten the design and implementation cycles of large-scale, real-time data acquisition and control systems. This paper details a data acquisition and real-time tomography system using LabVIEW RT for the bolometer diagnostic on the ASDEX Upgrade tokamak (Max Planck Institute for Plasma Physics, Garching, Germany). The transformation matrix for tomography is pre-computed based on the geometry of distributed radiation sources and sensors. A parallelized iterative algorithm is adapted to solve a constrained linear system for the reconstruction of the radiated power density. Real-time bolometer tomography is performed with LabVIEW RT. Using multi-core machines to execute the parallelized algorithm, a cycle time well below 1 ms is reached.
Keywords :
LABVIEW , ASDEX , Bolometer diagnostic , tomography , PXI , FPGA
Journal title :
Fusion Engineering and Design
Serial Year :
2011
Journal title :
Fusion Engineering and Design
Record number :
2358020
Link To Document :
بازگشت