Title of article :
Monte Carlo approach to define the refrigerator capacities for JT-60SA
Author/Authors :
Wanner، نويسنده , , Manfred and Barabaschi، نويسنده , , Pietro and Lamaison، نويسنده , , Valerie and Michel، نويسنده , , Fréderic and Reynaud، نويسنده , , Pascal B. Roussel، نويسنده , , Pascal، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Pages :
3
From page :
1511
To page :
1513
Abstract :
The JT-60SA cryogenic system shall provide refrigeration to keep the superconducting magnets and their structures at 4.4 K, cryo-pumps at 3.7 K, thermal shields at 80–100 K, and deliver a flow of 50 K helium to the current leads. A Monte Carlo method is proposed to determine the capacity contingencies for the refrigeration system. Attributing individual contingencies and distribution probability functions to the design variables allows the different load contributions to be statistically averaged. The total refrigeration contingency is derived for each temperature level from the 95% confidence level of the integrated distribution function.
Keywords :
Contingencies , Monte Carlo , JT-60SA , Cryogenics
Journal title :
Fusion Engineering and Design
Serial Year :
2011
Journal title :
Fusion Engineering and Design
Record number :
2358349
Link To Document :
بازگشت