Title of article :
Assessment of radiation maps during activated divertor moving in the ITER building
Author/Authors :
Ying، نويسنده , , Dongchuan and Zeng، نويسنده , , Qin and Qiu، نويسنده , , Yuefeng and Dang، نويسنده , , Tongqiang and Wu، نويسنده , , Yican and Loughlin، نويسنده , , Michael، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Pages :
5
From page :
2087
To page :
2091
Abstract :
As the main interface components between plasma and vacuum vessel, the divertor is foreseen to be removed to the hot cell for refurbishment during the 20 years of ITER operation. During this process, the activated divertor will cause a large increase of radiation in the ITER building. 3D analysis has been performed to assess the radiation maps throughout the ITER building for assisting the shielding design for personnel and sensitive equipment. The activation of the divertor has been determined by coupled neutron transport and inventory calculations, radiation maps have been obtained from gamma transport calculations. The neutron and gamma transport calculations have been performed by MCNP5 code with FENDL2.1library. The inventory calculations have been performed by FISPACT2007 code with EAF-2007 library. The results of these 3D decay gamma radiation maps are presented by pictures in this paper, including the biological dose maps and maps of heat deposition in electronic equipment.
Keywords :
Radiation maps , ITER , Divertor , Maintenance