Title of article :
Nuclear engineering of diagnostic port plugs on ITER
Author/Authors :
Pitcher، نويسنده , , C.S. and Barnsley، نويسنده , , R. and Feder، نويسنده , , R. and Hu، نويسنده , , Q. and Loesser، نويسنده , , G.D. and Lyublin، نويسنده , , B. and Padasalagi، نويسنده , , S. and Pak، نويسنده , , S. and Reichle، نويسنده , , R. and Sato، نويسنده , , K. and Udintsev، نويسنده , , V.S and Walker، نويسنده , , C. and Walsh، نويسنده , , M. and Zhai، نويسنده , , Y.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Pages :
8
From page :
667
To page :
674
Abstract :
The nuclear engineering infrastructure of port-based diagnostics on ITER is presented, including the equatorial and upper port plug generic designs, the adopted modular concept, the loads and associated load response and the remote handling. A modular approach is adopted for the internal shielding modules as this helps to reduce the dominant electromagnetic loads, reduces interfaces and accelerates remote handling. Extensive use of gun-drilling is employed to produce water channels in the stainless steel plate and forgings used to construct the port plugs and modules. The French Nuclear Code RCC-MR (2007) is employed in the design and the manufacturing. An integrated remote handling scheme is described, including a description of maintenance operations in the Hot Cell Facility.
Keywords :
Port plugs , Nuclear shielding , Diagnostics , Shut-down dose rate , remote handling , ITER
Journal title :
Fusion Engineering and Design
Serial Year :
2012
Journal title :
Fusion Engineering and Design
Record number :
2359375
Link To Document :
بازگشت