Title of article :
Design of the hypervapotron module for the EAST device
Author/Authors :
Wang، نويسنده , , Zhongwei and Song، نويسنده , , Yuntao and Huang، نويسنده , , Shenghong، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Pages :
4
From page :
868
To page :
871
Abstract :
In the EAST tokamak upgrade plan, the peak heat flux requirement to the PFC (plasma facing component) is 2 MW/m2, which doubles current design criteria, and needs improved cooling modules. In order to satisfy this demand and achieve the ability of cooling the next generation machine, the hypervapotron concept is chosen to be developed as a candidate method. Preparative design and optimization work is ongoing, which mainly based on the CFD (computational fluid dynamics) analysis presenting the sub-cooled boiling process in the module; in this paper, the boiling effect is confirmed compared to former single phase convection, then six different fin designs are compared as an optimization, as well as the clearance between the fin and the side wall, all these efforts ensure the quality of the design and prepare enough materials for the mock-up test.
Keywords :
Hypervapotron , CFD analysis , PFC components
Journal title :
Fusion Engineering and Design
Serial Year :
2012
Journal title :
Fusion Engineering and Design
Record number :
2360402
Link To Document :
بازگشت