Title of article :
Neutronics analysis of the IVVS/GDC plug in ITER
Author/Authors :
Leichtle، نويسنده , , D. and Fischer، نويسنده , , U. and Serikov، نويسنده , , A.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Pages :
5
From page :
1030
To page :
1034
Abstract :
A neutronics analysis has been performed to provide the input required for the design strategy for the In-Vessel Viewing System (IVVS) and the Glow Discharge Cleaning (GDC) plug units in the ITER tokamak. The focus of the analysis has been on operational loads to the GDC electrode head in the shielding position and on the activation and the decay photon radiation absorbed in the structural components of the entire system. To estimate the conditions for maintenance scenarios, the occupational dose rate around the isolated IVVS/GDC head has been calculated assuming the ITER SA2 irradiation scenario. The Rigorous 2 Step (R2S) method, developed previously at KIT, has been employed for the calculation of the shutdown dose rates. The GDC head, which is subjected to the highest neutron loads, gets heavily activated and dominates the decay gamma activity of the entire plug. Accordingly, the shutdown dose rate around the IVVS/GDC plug is dominated by the GDC electrode head. It is therefore recommended to separate the GDC head from the system prior to further operations inside the Hot Cell. All components, except the Be protective layer of the GDC probe, were shown to be classifiable as low level radwaste according to the French regulations.
Keywords :
neutronics , Monte Carlo , ITER , Occupational dose rates , Diagnostics
Journal title :
Fusion Engineering and Design
Serial Year :
2012
Journal title :
Fusion Engineering and Design
Record number :
2360471
Link To Document :
بازگشت