Abstract :
The TES, CPS and TMS are very important ancillary systems for operation of the TBM because most of the TBM experiment data will be got by operation of these systems. This paper introduces the progress of the R&D on these systems. A hydrogen isotope separation subsystem is integrated into the TES for accurate measurement of tritium as well as less tritium contamination hydrogen release into the environment compare with the original design of the TES. A tested assembly of a TES based on the results has been designed based on the results. Experiment results on the components show that the present design is feasible.
Keywords :
tritium , TES , TBM