• Title of article

    Thermo-mechanical tests on W7-X current lead flanges

  • Author/Authors

    Dhard، نويسنده , , Chandra Prakash and Rummel، نويسنده , , Thomas and Zacharias، نويسنده , , Daniel and Bykov، نويسنده , , Victor and Moennich، نويسنده , , Thomas and Buscher، نويسنده , , Klaus-Peter، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2013
  • Pages
    4
  • From page
    725
  • To page
    728
  • Abstract
    Fourteen pieces of high temperature superconducting current leads (CL) arranged in seven pairs, will be installed on the outer vessel of Wendelstein 7-X (W7-X) stellarator. In order to support the CL, it is provided with two glass fiber reinforce plastic (GFRP) flanges, namely, the lower cryostat flange (CF) remaining at room temperature and upper radial flange (RF) at about 5 K. Both the flanges i.e. CF & RF experience high mechanical loads with respect to the CL, due to the evacuation of W7-X cryostat, cool-down of cold mass including the CL, electro-magnetic forces due to current & plasma operations and self weight of CL. In order to check the integrity of these flanges for such mechanical loads, thermo-mechanical tests were carried out on these flanges at room temperatures and at liquid nitrogen (LN2) temperatures. The details of test set-up, results and modeling are described in the paper.
  • Keywords
    Wendelstein 7-X , Thermo-mechanical tests , Current leads
  • Journal title
    Fusion Engineering and Design
  • Serial Year
    2013
  • Journal title
    Fusion Engineering and Design
  • Record number

    2360899