Title of article :
Thermo-mechanical tests on W7-X current lead flanges
Author/Authors :
Dhard، نويسنده , , Chandra Prakash and Rummel، نويسنده , , Thomas and Zacharias، نويسنده , , Daniel and Bykov، نويسنده , , Victor and Moennich، نويسنده , , Thomas and Buscher، نويسنده , , Klaus-Peter، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
4
From page :
725
To page :
728
Abstract :
Fourteen pieces of high temperature superconducting current leads (CL) arranged in seven pairs, will be installed on the outer vessel of Wendelstein 7-X (W7-X) stellarator. In order to support the CL, it is provided with two glass fiber reinforce plastic (GFRP) flanges, namely, the lower cryostat flange (CF) remaining at room temperature and upper radial flange (RF) at about 5 K. Both the flanges i.e. CF & RF experience high mechanical loads with respect to the CL, due to the evacuation of W7-X cryostat, cool-down of cold mass including the CL, electro-magnetic forces due to current & plasma operations and self weight of CL. In order to check the integrity of these flanges for such mechanical loads, thermo-mechanical tests were carried out on these flanges at room temperatures and at liquid nitrogen (LN2) temperatures. The details of test set-up, results and modeling are described in the paper.
Keywords :
Wendelstein 7-X , Thermo-mechanical tests , Current leads
Journal title :
Fusion Engineering and Design
Serial Year :
2013
Journal title :
Fusion Engineering and Design
Record number :
2360899
Link To Document :
بازگشت