• Title of article

    Broadband dielectric mirrors for optical diagnostics in ITER

  • Author/Authors

    Orlovskiy، نويسنده , , Ilya and Andreenko، نويسنده , , Evgeny and Vukolov، نويسنده , , Konstantin and Mukhammedzyanov، نويسنده , , Timur and Tobengauz، نويسنده , , Alexander، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2013
  • Pages
    4
  • From page
    1284
  • To page
    1287
  • Abstract
    Specially designed multilayered dielectric mirrors are able to provide reflectivity over 95% in visible range and hence can help to improve the performance of optical diagnostics for use in ITER. Samples with TiO2/SiO2 and Nb2O5/SiO2 coatings were tested under heat loads following neutron irradiation to verify their resistance to ITER-relevant conditions. All samples survived the neutron irradiation. Reflectivity of TiO2/SiO2 samples degraded after heating, whereas Nb2O5/SiO2 samples showed no significant changes in all the tests. Additionally, influence of hydrocarbon contamination on samples reflectivity was experimentally examined. As a result, such an effect was found not to be significant, and Nb2O5/SiO2 coating is regarded to be acceptable for ITER applications.
  • Keywords
    Optical diagnostics , Dielectric mirrors , ITER
  • Journal title
    Fusion Engineering and Design
  • Serial Year
    2013
  • Journal title
    Fusion Engineering and Design
  • Record number