Title of article :
17 bit 4.35 mW 1 kHz Delta Sigma ADC and 256-to-1 multiplexer for remote handling instrumentation equipment
Author/Authors :
Verbeeck، نويسنده , , Jens and Van Uffelen، نويسنده , , Marco and Steyaert، نويسنده , , Michiel and Leroux، نويسنده , , Paul، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Abstract :
A radiation tolerant Delta-Sigma Analog-to-Digital Converter (ADC) and multiplexer is presented. The design features a 1.5 V, 17 bit ADC consuming 4.35 mW at a sample frequency of 1 MHz. The ADC features a bandwidth of 1 kHz and utilizes a Correlated Double Sampling technique (CDS) to remove offset and 1/f noise. The circuit maintains its 17 bit resolution upon a simulated radiation dose exceeding 1 MGy and varying temperatures between 0 °C and 85 °C. Next a multiplexer is presented. It can multiplex 256 channels at a clock frequency of 128 MHz or has a data throughput of 256 MSample/s. In addition the bit period of the multiplexer varies less then 1.5% due to the influence of temperature or radiation, which proves the temperature and radiation tolerance.
Keywords :
Delta Sigma ADC , multiplexer , Instrumentation link , Radiation hard electronics
Journal title :
Fusion Engineering and Design
Journal title :
Fusion Engineering and Design