• Title of article

    Development of a plasma driven permeation experiment for TPE

  • Author/Authors

    Buchenauer، نويسنده , , Dean and Kolasinski، نويسنده , , Robert and Shimada، نويسنده , , Masa and Donovan، نويسنده , , David and Youchison، نويسنده , , Dennis and Merrill، نويسنده , , Brad، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2014
  • Pages
    5
  • From page
    1014
  • To page
    1018
  • Abstract
    Experiments on retention of hydrogen isotopes (including tritium) at temperatures less than 800 °C have been carried out in the Tritium Plasma Experiment (TPE) at Idaho National Laboratory [1,2]. To provide a direct measurement of plasma driven permeation in plasma facing materials at temperatures reaching 1000 °C, a new TPE membrane holder has been built to hold test specimens (≤1 mm in thickness) at high temperature while measuring tritium permeating through the membrane from the plasma facing side. This measurement is accomplished by employing a carrier gas that transports the permeating tritium from the backside of the membrane to ion chambers giving a direct measurement of the plasma driven tritium permeation rate. Isolation of the membrane cooling and sweep gases from TPEʹs vacuum chamber has been demonstrated by sealing tests performed up to 1000 °C of a membrane holder design that provides easy change out of membrane specimens between tests. Simulations of the helium carrier gas which transports tritium to the ion chamber indicate a very small pressure drop (∼700 Pa) with good flow uniformity (at 1000 sccm). Thermal transport simulations indicate that temperatures up to 1000 °C are expected at the highest TPE fluxes.
  • Keywords
    permeation , tritium , PLASMA
  • Journal title
    Fusion Engineering and Design
  • Serial Year
    2014
  • Journal title
    Fusion Engineering and Design
  • Record number

    2362227