Title of article :
Optimized mass flow rate distribution analysis for cooling the ITER Blanket System
Author/Authors :
Pérez، نويسنده , , Germلn and Mitteau، نويسنده , , Raphaël and Furmanek، نويسنده , , Andreas G. Martin، نويسنده , , Alex and Raffray، نويسنده , , A. Rene and Merola، نويسنده , , Mario and Sabourin، نويسنده , , Flavien، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
6
From page :
1324
To page :
1329
Abstract :
This paper presents the rationale to the optimization of water distribution in ITER blanket modules, meeting both Blanket System requirements and interface compliance requirements. y challenging constraints include to: be compatible with the overall water allocation (3140 kg/s for 440 wall mounted BMs); meet the critical heat flux margin of 1.4 in the plasma facing units; meet a maximum temperature increase of 70 °C at the outlet of each single BM; and ensure that water velocity is less than 7 m/s in all manifolds, and that the pressure drops of all BMs can be equilibrated. The methodology and the successful result are presented.
Keywords :
ITER , Critical heat flux , Blanket system , Mass flow rate
Journal title :
Fusion Engineering and Design
Serial Year :
2014
Journal title :
Fusion Engineering and Design
Record number :
2362525
Link To Document :
بازگشت