Title of article
Shutdown dose rate assessment with the Advanced D1S method: Development, applications and validation
Author/Authors
Villari، نويسنده , , R. and Fischer، نويسنده , , U. and Moro، نويسنده , , F. and Pereslavtsev، نويسنده , , P. and Petrizzi، نويسنده , , L. and Podda، نويسنده , , S. and Serikov، نويسنده , , A.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2014
Pages
5
From page
2083
To page
2087
Abstract
The present paper addresses the recent developments and applications of Advanced-D1S to the calculations of shutdown dose rate in tokamak devices. Results of benchmarking with measurements and Rigorous 2-Step (R2S) calculations are summarized and discussed as well as limitations and further developments. The outcomes confirm the essential role of the Advanced-D1S methodology and the evidence for its complementary use with the R2Smesh approach for the reliable assessment of shutdown dose rates and related statistical uncertainties in present and future fusion devices.
Keywords
MCNP5 , JET , FISPACT , ITER , Advanced-D1S , Shutdown dose rate